Category : geothermal
Category : geothermal
Cupro Nickel heat exchanger. 2 stage Ultra- Tech Scroll Compressor – Variable speed Fan, Hot Water Generator- Tin Plated coil. 18.3 EER 3.8 COP ground loop. Single Phase 208/230 voltage. 22.4″ W X 26.0″D X 46.5 H 208 lbs. 19.2 FLA 22.4 min circuit amps. We not only sell geothermal, we are licensed experts in
Left return (right available). 20.05 EER 3.8 COP ground loop. 25.4″ W X 30.6″D X 58.5 H 475 lbs. We not only sell geothermal, we are licensed experts in the field. We will gladly help with all of your geothermal needs. Cupro nickel heat exch. Geothermal Products is the nations no. 1 resource for geothermal
2 stage Ultra- Tech Scroll Compressor – Variable speed Fan, Hot Water Generator- Tin Plated coil – This unit has internal variable speed flow center. 19.05 EER 3.6 COP ground loop. Single Phase 208/230 voltage. 22.4″ W X 26″D X 46.5 H 244 lbs. 25.3 FLA 29.7 min circuit amps. We not only sell geothermal,
Single phase 208/230 voltage 25.2 min circuit amps 21.4 FLA 22.4 W X 26.0 D X 46.5 H 233 lbs. 2 ton 2 stage unit. Desuperheater and ECM motor/Upflow B&D QT 2 pump flow center Hose kit and fittings Thermostat (3 heat/2 cool). Interior manifold 3 rolls of 600 feet lengths of 3/4” hdpe geothermal
Right return (left available). 20.05 EER 3.8 COP ground loop. Single Phase 208/230 voltage. 25.4″ W X 30.6″D X 58.5 H 485 lbs. We not only sell geothermal, we are licensed experts in the field. We will gladly help with all of your geothermal needs. Geothermal Products Geothermal heat Pump. 6 ton Climatemaster TEV072BGD00CRTS. Geothermal
2 stage Ultra- Tech Scroll Compressor – Left return, Variable speed Fan, Hot Water Generator- Tin Plated coil. 18.3 EER 3.8 COP ground. 22.4w x 26.0 d x 46.5h. Single Phase 208/230 voltage. 22.4″ W X 26.0″D X 46.5 H 208 lbs. 19.2 FLA 22.4 min circuit amps. This unit was used in our training
2 stage Ultra- Tech Scroll Compressor – Right return, Variable speed Fan, Hot Water Generator- Tin Plated coil – This unit has internal variable speed flow center. 18.3 EER 3.8 COP ground loop. Single Phase 208/230 voltage. 25.4″ W X 29.3″D X 50.5 H 299 lbs. 28.6 FLA 33.9 min circuit amps. We not only
Single phase 208/230 voltage 25.2 min circuit amps 21.4 FLA 22.4 W X 26.0 D X 46.5 H 233 lbs. 2 ton 2 stage. Desuperheater and ECM motor/Upflow B&D QT 1 pump flow center Hose kit and fittings Thermostat (3 heat/2 cool). Interior manifold 2 rolls of 600 feet lengths of 3/4” hdpe geothermal pipe
Single phase 208/230 voltage 25.2 min circuit amps 21.4 FLA 22.4 W X 26.0 D X 46.5 H 233 lbs. 4 ton 2 stage. Desuperheater and ECM motor/Upflow B&D QT 2 pump flow center Hose kit and fittings Thermostat (3 heat/2 cool). Interior manifold 4 rolls of 600 feet lengths of 3/4” hdpe geothermal pipe
6 ton 2 stage. Desuperheater and ECM motor/Upflow B&D QT 2 pump flow center Hose kit and fittings Thermostat (3 heat/2 cool). Interior manifold 6 rolls of 600 feet lengths of 3/4” hdpe geothermal pipe or 6 rolls of 410 feet lengths of hdpe loops (205 up/205 down with ubend) Photo is a stock photo.